Multi-Channel Charge Readout Amplifier/Shaper ASICS
- RENA-3™:
Readout Electronics for Nuclear Application. A 36-channel charge
sensitive amplifier/shaper ASIC chip with trigger output and sparse
readout mode for reading out position sensitive solid state detectors.
The RENA-3 is an improved version of the prototype
RENA-2 design which supersedes NOVA’s earlier 32-channel
RENA chip. UCSD's HEXIS project
uses the RENA chip.
- XENA™:
X-ray ENergy-binning Applications Applications. An integrated
circuit for the fast readout of solid-state x-ray and gamma ray
detectors with multi-energy capability, designed for the high-throughput
N-Energy X-ray Image Scanning (NEXIS) system and similar x-ray
imaging technologies. XENA and NEXIS supersede FESA and ABIS.
- MPX-08™:
Multianode Photomultiplier Electronics. A micropower charge-integrating
readout system optimized for pulse analysis for photomultiplier
tubes and similar detectors.
- ACE™:
Advanced Charge-conversion Electronics. A multi-channel charge
sensitive amplifier/shaper ASIC chip with trigger output, wide
dynamic range and on board ultra linear Wilkinson ADC for reading
out multianode PMTs, APD arrays and position sensitive solid state
detectors.
X-ray Detector Module
- NEXIS™:
N-Energy x-ray Image Scanning. NEXIS is modular detector system
designed for high -flux, multiple-energy x-ray imaging. It consists
essentially of detector boards equipped with linear (CdZnTe) detector
arras read out by XENA signal processor
chips. XENA and NEXIS supersede FESA and ABIS
X-Ray Pixel Detector
- MARY-N™:
A pixel detector readout ASIC chip with 192 x 384 array of 50
x 50 micron pixel size for high resolution, high dynamic range
industrial or medical x-ray imaging such as digital radiography,
nondestructive evaluation or digital MAmmogRaphY. A new version
of this chip is currently under development, as well as one with
a 100 x 100 micron pixel pitch.
- HILDA™: The HILDA IC (Hyperspectral Imaging with Large Detector Arrays) is a 16 x 16, 500mm pitch array of channels designed for high-rate photon counting and multiple-energy binning up to eight bands. Like the DANA, it is intended for use in flip-chip connection with a matching 2D detector pixel array. Such a 16 x 16, 500mm pitch CZT pixel array detector is currently in fabrication. The main application envisioned for this chip is munitions inspection.
- DANA™: The DANA IC (Detector Array for Nuclear Applications Integrated Circuit) is a 16 x 16, 500mm pitch array of channels with a charge sensitive amplifier/shaper, trigger output and sparse readout intended for use in flip-chip connection with a spectroscopy-grade 2D detector pixel array. The advantages of such a readout channel array include lower input capacitance and noise, finer pixel pitch, more compact sensor readout assembly and ease of tiling array units into a large-area 2D array. On the other hand, its format entails the challenge of fitting complex circuitry within the unit cell area, developing the matching detector pixel array, and finding a solution for reliable and cost-effective IC-detector bonding.
Voltage to Frequency Converter
- N101VTF™:
A four channel ultra high linearity (<50ppm) Voltage-to-Frequency
Converter NIM module with onboard calibration capability.
Hand held Portable Substance Detector
- CINDI™:
Hand held portable substance detector. Can also be used for finding
the position of obstruction in clogged pipes, detecting neutrons
and gamma rays for controlling and monitoring nuclear proliferation.
|